WNS Integrated Condensing Steam Boiler
- New feather-wing tubes replace traditional smoke tubes, with high heat transfer efficiency, improved thermal efficiency, and reduced flue gas temperature.
- New corrugated furnace liners replace straight-segment corrugated composite furnace liners, improving heat transfer efficiency and better offsetting thermal stress.
- With new technical support, the boiler volume is reduced by 40%.
- The optimized FGR flue gas extraction port greatly shortens the length of FGR pipelines, saving space and improving the drawback of condensate water entering the fan.
- The economizer and condenser are integrated, featuring small volume and strong scale tolerance.
- All exposed parts are treated by shot blasting process and sprayed with high-temperature resistant paint, ensuring long service life.
- Large steam space with built-in steam-water separation device ensures steam dryness and quality.
- Reduced water volume enables fast steam response time.
- Shell-type full-wet back downstream double-return structure, micro-positive pressure combustion, low heat load, and low nitrogen oxide emissions.
- Both front smoke box and panel adopt double-layer sealing structure, and airtightness detection is carried out to ensure sealing.
- Detachable explosion-proof door ensures safe boiler operation and can be used as a furnace inspection hole.
- Adopts variable frequency continuous water supply system for stable operation.
- The boiler has a high degree of automatic control, high operation reliability, and simple and intuitive operation.
-

technical parameter
WNS1 1.0-7-Q
WNS2 1.0-7-Q
WNS3 1.0-7-Q
WNS4 1.0-7-Q
WNS5 1.0-7-Q
WNS6 1.0-7-Q
WNS10 1.0-7-Q
WNS15 1.0-7-Q
WNS20 1.0-7-Q
WNS25 1.0-7-Q
WNS30 1.0-7-Q
rated capacity
t/h
1
2
3
4
6
8
10
15
20
25
30
Rated steam pressure
Mpa
1.0
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
Rated inlet temperature
℃
20
20
20
20
20
20
20/104
20/104
20/104
20/104
20/104
Total electrical power
kw
6
8.5
15
15
22
30.5
38
67
91.5
127.5
143
Rated thermal efficiency
%
102.47
102.12
102.61
102.8
102.83
102.62
102.41
102.79
103.08
102.53
102.45
gas consumption
Nm³/h
71.69
140.60
217.32
274.85
412.14
550.69
689.78
1033.749
1378.099
1722.63
2067.23
Main outlet
DN
DN50
DN65
DN80
DN100
DN125
DN125
DN150
DN200
DN200
DN250
DN250
relief valve connection
DN
DN40
DN60
DN100
DN150
DN65*2
DN65*2
DN80*2
DN100*2
DN100*2
DN100*2
DN105*2
blast-hole
DN
DN25
DN40
DN40
DN50
DN50
DN50
DN65
DN65
DN65
DN65
DN65
drain outlet
DN
DN40
DN40
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN50
chimney
mm
400*720
409*340
469*430
469*497
780*474
780*684
780*780
969*889
980*1183
980*1183
1009*1490
long
mm
4258
5118
5330
5946
6030
7122
8160
8125
8863
9365
8900
wide
mm
2505
2505
2844
2943
3252
3413
3468
4035
4212
4212
5950
tall
mm
2929
2929
3412
3312
3688
4114
4310
4743
5177
5177
5800
floor space
m³
10.92
13.15
15.16
17.50
19.61
24.31
28.30
32.78
37.33
39.45
52.96
Net weight of boiler
t
6.36
7.50
9.29
9.88
13.07
17.03
20.07
20.08
35.88
40.88
50.88
Full water weight
t
7.72
9.69
13.45
13.95
18.68
25.69
29.27
42.10
55.55
61.86
76.85
Water volume
L
1360
2190
4160
4070
5610
8660
9200
16020
19670
20980
23760