Leave Your Message

Integral Superheated Steam Water-tube Boiler

  • The superheater is installed behind the flue gas outlet of the main body. With a low inlet flue gas temperature, the superheater operates under superior conditions, effectively avoiding rapid overheating, burnout, and tube explosion of the superheater tubes.  
  • The superheater uses finned tubes, providing a large heat absorption area.  
  • The surface-type attemperator is adopted, where the attemperating water does not directly contact the superheated steam. It is suitable for various medium and low-pressure boilers and has no special requirements for the water quality of the cooling water.  
  • Installation and maintenance are simple and convenient. Since the superheater is not located inside the furnace body, maintenance can be carried out by directly opening the shell plates on both sides of the superheater.05.jpg

    Product Parameter

    unit

    07-2000

    07-4000

    07-6000

    07-8000

    07-10000

    07-15000

    07-20000

    07-25000

    07-30000

    rated capacity

    t/h

    2

    4

    6

    8

    10

    15

    20

    25

    30

    power rating

    Kw

    12

    22

    34

    52

    56

    79

    110

    134

    150

    gas pressure

    Kpa

    15-20

    15-20

    20-25

    20-25

    20-30

    30-40

    30-40

    30-40

    30-40

    Gas port size

    mm

    DN50

    DN50

    DN100

    DN100

    DN100

    DN125

    DN125

    DN150

    DN200

    Main valve bore

    mm

    DN65

    DN100

    DN125

    DN150

    DN150

    DN200

    DN200

    DN200

    DN250

    Inlet diameter

    mm

    DN40

    DN50

    DN50

    DN50

    DN65

    DN65

    DN65

    DN65

    DN65

    Nozzle size

    mm

    DN40

    DN50

    DN50

    DN50

    DN50

    DN50

    DN50

    DN50

    DN50

    Safety valve size

    mm

    DN50

    DN60

    DN65

    DN65

    DN80

    DN100

    DN100

    DN100

    DN125

    Chimney (height*width)

    mm

    468*340

    448*465

    540*648

    740*692

    740*870

    740*1260

    925*1190

    925*1190

    1090*1480

    hauled weight

    t

    8.47

    15.84

    17.65

    24.7

    28.23

    31.88

    40.26

    45.26

    58.06

    Running weight

    t

    10.66

    20.6

    23.55

    32.96

    36.43

    47.08

    56.96

    65.24

    81.82

    water capacity

    m3

    2.19

    4.76

    5.9

    8.26

    8.2

    15.2

    16.7

    19.98

    23.76

    Installation size-length

    mm

    4652

    5798

    6056

    6973

    7063

    8145

    8152

    8652

    8400

    Installation size-width

    mm

    2810

    3472

    3658

    3857

    3650

    5274

    4800

    4800

    5950

    Installation size-high

    mm

    2919

    3680

    4087

    4460

    4764

    5164

    5650

    5650

    5800

    Rated water supply temperature: 20℃, thermal efficiency: 103.8% rated steam pressure: 1.25Mpa saturated steam temperature: 194℃ power supply requirement: 380V/50Hz

    Quite a lot of heat

    *10^6kcal

    129.05

    258.09

    387.13

    516.18

    645.22

    967.84

    1290.45

    1613.06

    1935.67

    Rated gas consumption

    Nm3/h

    136.02

    272.04

    408.05

    544.07

    680.1

    1020.14

    1360.18

    1700.23

    2040.27

    Rated water supply temperature 90℃, thermal efficiency 97% rated steam pressure: 1.25Mpa saturated steam temperature: 194℃ power supply requirement: 380V/50Hz

    Quite a lot of heat

    ×106kcal

    115.06

    230.12

    345.18

    460.24

    575.3

    862.95

    1150.59

    1438.24

    1725.89

    Rated gas consumption

    Nm3/h

    129.78

    259.56

    389.34

    519.12

    648.9

    972.34

    1297.79

    1622.24

    1946.69

    Leave Your Message