Electric Hot Water Boiler
Electric heating boilers are mainly composed of the boiler body, electric control box, and control system. They are characterized by being environmentally friendly, clean, pollution-free, noiseless, and fully automatic. With the reduction and significant price increase of finite energy sources, electric heating boilers, as emerging boiler equipment, are increasingly recognized by everyone. The electric heating tube is the core component of an electric heating boiler. The product uses direct electric heating tubes, which are convenient for replacement and maintenance. Meanwhile, the surface load is low, which prolongs the service life.
Constant pressure
|
Project model |
electrical rating |
current |
Recirculating water |
Hot water quantity (△t=40℃) |
Boiler size |
drain outlet |
Inlet/outlet |
Open vents |
weight |
remarks |
||
|
L |
W |
H |
||||||||||
|
unit |
kW |
A |
m³/h |
kg/h |
mm |
mm |
mm |
mm |
mm |
mm |
t |
|
|
CWDR.95 -95/70-Ⅱ |
360 |
547 |
12 |
7500 |
1680 |
1146 |
1535 |
DN50 |
DN80 |
DN80 |
0.638 |
an organic whole |
|
CWDR.47 -95/70-Ⅱ |
480 |
729 |
16 |
10071 |
2000 |
1300 |
1620 |
DN50 |
DN80 |
DN80 |
0.849 |
|
|
CWDR.0.7 -95/70-Ⅱ |
720 |
1094 |
24 |
15000 |
2000 |
1100 |
1840 |
DN50 |
DN100 |
DN80 |
1.4 |
split type |
|
CWDR1.0 -95/70-Ⅱ |
1050 |
1595 |
34.3 |
21429 |
2580 |
1500 |
2152 |
DN40 |
DN125 |
DN100 |
2 |
|
|
CWDR1.75 -95/70-Ⅱ |
1800 |
2735 |
60 |
37500 |
2650 |
1790 |
2540 |
DN40 |
DN125 |
DN125 |
2.75 |
|
|
common use |
Rated outlet/inlet temperature |
℃ |
95/70 |
Rated thermal efficiency |
% |
98 |
Use power |
V/Hz |
380/50 |
|||
Pressure type
|
Project model |
electrical rating |
thermal power |
current |
Recirculating water |
Hot water quantity (△t=40℃) |
Boiler size |
drain outlet |
blast-hole |
delivery port |
weight |
||
|
L |
W |
H |
||||||||||
|
unit |
kW |
kcal/h |
A |
m³/h |
kg/h |
mm |
mm |
mm |
mm |
mm |
mm |
t |
|
WDR0.7 -1.0/95/70-Ⅱ |
720 |
60.7*104 |
1094 |
24 |
15000 |
2640 |
1350 |
2830 |
DN40 |
DN100 |
DN100 |
2.483 |
|
WDR1.2 -1.0/95/70-Ⅱ |
1200 |
101.1*104 |
1823 |
41 |
25714 |
2860 |
1615 |
3065 |
DN40 |
DN125 |
DN125 |
2.511 |
|
WDR2.4 -1.6/95/70-Ⅱ |
1500 |
126.4*104 |
2279 |
48.2 |
30000 |
3070 |
2240 |
3048 |
DN50 |
DN125 |
DN125 |
4.759 |
|
WDR2.1 -1.0/115/95/70-Ⅲ |
2250 |
189.6*104 |
3375 |
40.1 |
45000 |
4060 |
2240 |
3212 |
DN50 |
DN125 |
DN125 |
4.345 |
|
WDR2.5 -1.0/115/95/70-Ⅲ |
3000 |
242.8*104 |
4558 |
53.5 |
60000 |
4173 |
2540 |
3512 |
DN50 |
DN125 |
DN125 |
5.138 |
|
common use |
Inlet and outlet water temperature |
℃ |
95/70 |
Circulating thermal efficiency |
% |
98 |
Use power |
V/Hz |
380/50 |
|||